HOME » PRODUCTS & SOLUTIONS » Vacuum Inspection » Technical data

Technical data

Measurement method

Continuous in-line vacuum inspection by measuring the deflection of container closures.

INDEC VA 100 

Max. test speed    

600 units/minute

Field of application

Metal closures

Sensor head

2 inductive sensors

18 mm Ø sensor

Closures from 38 to 110 mm Ø

Working distance

2 to 5 mm

30 mm Ø sensor

Closures from 48 to 110 mm Ø

Working distance

5 to 9 mm

INDEC VA 200

Max. test speed

1,200 units/minute

Field of application

Reflective materials

Sensor head

Optical sensor

Closures from 30 to 110 mm Ø

Working distance > 100 mm

Connection to power supply

Rated voltage

88 to 264 VAC, 47 to 63 Hz

Wattage

65 W

Environment

Operating temperature

0 to 50°C

Housing protection class

IP69K